OM-492 Page 36

Trouble

Remedy

Engine does not go to low (idle) speed
with Engine Control switch in Run/Idle
position.

Be sure Engine Control switch S1 is in Run/Idle position.

Remove all weld and auxiliary power loads.

Turn off remote device connected to Remote 14 receptacle RC5 (see Section 4-8).

Check for obstructed movement of throttle solenoid linkage.

Have Factory Authorized Service Agent check voltage regulator board PC8 and current transformer
CT1.

Reset circuit breaker CB9 (see Section 7-8).

Engine does not go to high (run) speed
when auxiliary power or large weld
load is applied with Engine Control
switch in Run/Idle position.

Place Engine Control switch in the Run position. Have Factory Authorized Service Agent check unit.

Engine uses oil during run-in period;
wetstacking occurs.

Dry engine (see Section 9 and engine manual).

Coolant recovery tank continuously
overflows.

Bleed air from radiator, and replace lost coolant (see Section 4-3).