OM-492 Page 32

7-9.

Voltmeter/Ammeter Help Displays

Use the voltmeter/ammeter help displays to
help determine the cause of no weld output.
When a help display is shown, the inverter
module weld output has stopped but the en-
gine continues to run. Correct the problem
before resuming operation.

The display screen resets when the fault is
corrected.

.

All directions are in reference to the front
of the unit. All circuitry referred to is lo-
cated inside the inverter module.

1

Help 0 Display

Indicates a shorted thermistor RT2 on the left
side of the unit. If this display is shown, con-
tact a Factory Authorized Service Agent.

2

Help 1 Display

Indicates a malfunction in the primary power
circuit possibly caused by applying a high
weld load at idle speed. Turn Engine Control
switch to Run position. If problem continues,
contact a Factory Authorized Service Agent.

3

Help 2 Display

Indicates a malfunction in the thermal protec-
tion circuitry located on the left side of the unit.
If this display is shown, contact a Factory Au-
thorized Service Agent.

4

Help 3 Display

Indicates the left side of the unit has over-
heated. The unit has shut down to allow the
fan to cool it (see Section 3-3). Operation will
continue when the unit has cooled.

5

Help 4 Display

Indicates a malfunction in the thermal protec-
tion circuitry located on the right side of the
unit. If this display is shown, contact a Factory
Authorized Service Agent.

6

Help 5 Display

Indicates the right side of the unit has over-
heated. The unit has shut down to allow the
fan to cool it (see Section 3-3). Operation will
continue when the unit has cooled.

7

Help 6 Display

Indicates that the input voltage is too low and
the unit has automatically shut down. Opera-
tion will continue when the voltage is within the
acceptable lower range limit (15% below the
applicable input voltage). If this display is
shown, have a Factory Authorized Service
Agent check the power generator output volt-
age.

8

Help 7 Display

Indicates that the input voltage is too high and
the unit has automatically shut down. Opera-
tion will continue when the voltage is within the
acceptable upper range limit (15% above the
applicable input voltage). If this display is
shown, have a Factory Authorized Service
Agent check the power generator output volt-
age.

9

Help 8 Display

Indicates a malfunction in the secondary pow-
er circuit of the unit. If this display is shown,
contact a Factory Authorized Service Agent.

10 Help 9 Display

Indicates a shorted thermistor RT1 on the
right side of the unit. If this display is shown,
contact a Factory Authorized Service Agent.

1

A

V

2

A

V

3

A

V

HE.L

P–0

HE.L

P–1

HE.L

P–2

4

A

V

HE.L

P–3

5

A

V

HE.L

P–4

6

A

V

7

A

V

8

A

V

HE.L

P–5

HE.L

P–6

HE.L

P–7

9

A

V

HE.L

P–8

10

A

V

HE.L

P–9

802 174-E

Advertising