18
.
Disconnect the fingerprint reader board cable (1) from the fingerprint reader board.
19
.
If it is necessary to replace the fingerprint reader board, remove the Phillips PM2.0×4.0 screw (2)
that secures the fingerprint reader board and bracket to the display bezel.
20
.
Remove the fingerprint reader board bracket (3).
21
.
Lift the left side of the fingerprint reader board (4) and remove the board from the display bezel.
NOTE:
The fingerprint reader board and bracket are available using spare part number
441121-001.
22
.
If it is necessary to replace the display inverter, remove the Phillips PM2.0×4.0 screw (1) that secures
the inverter to the display enclosure.
23
.
Disconnect the backlight cable (2) and the display panel cable (3) from the inverter.
24
.
Remove the display inverter (4).
NOTE:
The display inverter is available using spare part number 441119-001.
ENWW
Component replacement procedures 57