Installation of Fireplace

CAUTION! Risk of Cuts/Abrasions. Wear protective

gloves and safety glasses during installation. Sheet metal

edges are sharp.

A. Things to Consider

• Location(s) of outside air kit(s)

• Gas line piping

B. Position the Fireplace

• Place the fireplace on a continuous flat surface.

• Follow framing instructions in Section 6.

WARNING! Risk of Fire! Prevent contact with sagging,

loose insulation.

DO NOT install against vapor barriers or exposed

insulation.

• Secure insulation and vapor barriers.

• Provide minimum air space clearances at the sides

and back of the fireplace assembly as outlined in

Section 6.

Raised Platform

Floor

2 in.

(51 mm)

1 in. (25 mm) min.

overlap

2 in.

(51 mm)

Top piece must overlap

bottom piece

Metal strips are placed 2 in. (51 mm)

under the front of the fireplace and must

extend beyond the front and sides of

fireplace opening by 2 in. (51 mm).

1 in. (25 mm) overlap

Minimum

Figure 7.1 Position the Protective Metal Hearth Strips

C. Place Protective Metal Hearth Strips

WARNING! Risk of Fire! Metal hearth strips MUST be

installed.

DO NOT cover metal strips with combustible

materials. Sparks or embers may ignite flooring.

• Refer to Figures 7.1 and 7.2.

• Locate the two metal hearth strips measuring approximately

26 in. x 4 in. (660 mm x 102 mm) included with this

fireplace.

• Slide each metal strip 2 in. (51 mm) under front edge of

fireplace.

• Overlap strips in the middle of fireplace opening by 1 in

(25 mm) minimum..

• Metal strips must extend beyond the front and sides of the

fireplace opening by at least 2 in. (51 mm).

• Protect the front of a platform elevated above the hearth

extension with metal strips (not included with fireplace)

per Figure 7.2. See Section 12 for hearth extension

instructions.

D. Level Fireplace

• Level fireplace side-to-side and front-to-back.

• Shim with non-combustible material as necessary.

• Secure fireplace to framing with nailing flanges with a

minimum of two fasteners per nailing flange.

• Check fireplace opening for square to ensure proper fit of

glass doors. Measure diagonals of fireplace opening to

make sure they are equal.

Figure 7.2 Protect the Front of an Elevated Platform

Heatilator • Birmingham BIR42-B • 4059-681C• 9/12