Hearth and Home Technologies BIR42-B User Manual

Page 22

Advertising
background image

22

Outlet placed

higher than 3 ft

below the

termination cap

Attic space

Garage or

combustible

liquids storage

Outlet blocked by

snow, leaves, etc.

Clear area

outside

house or in

ventilated

crawl space

YES

NO

NO

NO

NO

Factory-built

fireplace

Use only duct materials specified by manufacturer (preferably

with short run or mainly straight duct, except small dip for cold

air trap which will help prevent flow of cold air).

Figure 7.4 Outside Air Placement

Outside air installed

on both sides (right

side not shown)

Heatilator • Birmingham BIR42-B • 4059-681C • 9/12

3 ft min. from

top of uppermost

chimney section

to air inlet.

Figure 7.3 Outside Air Inlet Locations