Chimney assembly – Hearth and Home Technologies BIR42-B User Manual

Page 24

Advertising
background image

24

Chimney must extend

beyond combustible

roof structure

Maintain minimum

height of chimney

above roof

Additional

support for

tall chimneys

Install roof flashing

according to minimum

requirements

Maintain minimum

clearances to

combustibles as

specified

Offsets/returns

may not exceed

30° from vertical

Lock chimney

sections together

firmly to resist

movement

Ceiling firestops

are required where

chimney passes

through ceiling or

floor

Support straps for offsets

(not shown) must be

secured to adequate framing

Termination Cap

Storm Collar

Offsets/returns must be

secured with the screws

provided (outer pipe only)

Attic shield not shown

(see Figure 6.2)

Figure 8.1 Typical Chimney System - Guidelines for Chimney System Installation

8

Chimney Assembly

NOTICE: Chimney performance may vary.
• Trees, buildings, roof lines and wind conditions affect

performance.

• Chimney height may need adjustment if smoking or

overdraft occurs.

Heatilator • Birmingham BIR42-B • 4059-681C • 9/12