A. Gas Log/Lighter Provision

WARNING! Fire and/or Asphyxiation Risk! Use with solid

wood fuel or decorative gas appliance only. Gas fire gener-

ates fumes.

• DO NOT install unvented gas logs

• Damper must be locked fully open when gas logs are

installed

Firebox

Repack

insulation

knockout

Combustible

materials

Maintain air clearance

to combustibles.

Gas line

Combustible materials

may be located at zero

clearance to gas line

beyond 4 in. (102 mm)

from fireplace side.

Gas line

1 1/2 in. (38 mm)

air space around

pipe

Refractory

Seal with

fireplace mortar

or non-combust-

ible sealant

4 in.

(102 mm)

Outer shell

of fireplace

Figure 13.1 Gas Line Installation

13

Accessories

B. Wood Burning Inserts

A certified gas log lighter or decorative gas log set can be

installed in this fireplace.
• Maximum input is 150,000 BTU/hr.

• Decorative gas appliance must be certified to

ANSI Z21.60

“Standard for Decorative Gas Appliances for Installation

in Vented Fireplaces”.

• Must be installed in accordance with the

National Fuel

Gas Code, ANSI Z223.1.

• A gas log set must incorporate a gas shutoff.

• Gas log set requires the damper to be locked fully open.

• A listed automatic damper system with safety interlock may

be used in this fireplace with only compatible, listed gas log

sets. See damper system manufacturer’s instructions.

• Knockouts are provided on both sides of the fireplace for

1/2 in. (13 mm) iron pipe.

• A locating dimple (see Figure 13.2) is located on both sides

of the fireplace in the molded brick panels for drilling a 1

in. (25 mm) diameter hole for installation of a gas line.

After the panel is installed, drill the hole for the gas line.

• Seal panel around pipe with fireplace mortar or a high

temperature, non-combustible sealant.

WARNING! Risk of Fire! Improper installation of wood

inserts may cause fireplace or chimney system to overheat.
If a wood burning insert is being installed in this fireplace,

Hearth & Home Technologies recommends full reline of the

chimney.
• Cooling air openings at the top of the chimney must not

be obstructed in any manner.

• Hearth & Home Technologies recommends securing the

reline at the top of the flue and using the cap certified for

use with this fireplace system.

Gas Line

Dimple

Gas Line

Dimple

Figure 13.2 Gas Line Dimples

Heatilator • Birmingham BIR42-B • 4059-681C• 9/12