Power Cord Set Requirements

Maintenance and Service Guide

B–3

United Kingdom

BSI

1

United States

UL

2

Notes

1. The flexible cord must be <HAR> Type HO5VV-F, 3-conductor, 1.0 mm

²

conductor size. Power cord set fittings (appliance coupler and wall plug)
must bear the certification mark of the agency responsible for evaluation in
the country where it will be used.

2. The flexible cord must be Type SPT-3 or equivalent, No. 18 AWG,

3-conductor. The wall plug must be a two-pole grounding type with a NEMA
5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.

3. The appliance coupler, flexible cord, and wall plug must bear a “T” mark and

registration number in accordance with the Japanese Dentori Law. The
flexible cord must be Type VCT or VCTF, 3-conductor, 1.00 mm² conductor
size. The wall plug must be a two-pole grounding type with a Japanese
Industrial Standard C8303 (7 A, 125 V) configuration.

3-Conductor Power Cord

Set Requirements

(Continued)

Country

Accredited Agency

Applicable Note
Number