6. volt-ampere curve, 1. installing welding generator – Hobart Welding Products CHAMPION OM-493 User Manual

Page 16

Advertising
background image

OM-493 Page 12

3-6.

Volt-Ampere Curve

ST-191 555

The volt-ampere curve shows the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.

SECTION 4 – INSTALLATION

4-1.

Installing Welding Generator

install1 12/99 – Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854

Y

Do not weld on base. Weld-
ing on base can cause fuel
tank fire or explosion. Bolt
unit down using holes pro-
vided in base.

Y

Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.

1

Generator Base

2

Metal Vehicle Frame

3

Equipment Grounding
Terminal

4

Grounding Cable

Use #10 AWG or larger insulated
copper wire.

Y

If unit does not have GFCI re-
ceptacles, use GFCI-
protected extension cord.

1

2

Electrically bond genera-
tor frame to vehicle frame
by metal-to-metal contact.

GND/PE

3

4

2

OR

OR

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

OR

Movement

Airflow Clearance

Location

Grounding

Y

Do not lift unit from end.

Advertising