2. optional auxiliary power receptacles – Hobart Welding Products CHAMPION OM-493 User Manual

Page 23

Advertising
background image

OM-493 Page 19

6-2.

Optional Auxiliary Power Receptacles

Ref. ST-192 519 -A

Y

If unit does not have GFCI re-
ceptacles, use GFCI-
protected extension cord.

.

Auxiliary power decreases as
weld current increases.

Set Fine Adjust control R1 at 10
for full auxiliary power.

Combined output of all receptacles
limited to 8.5 kVA/kW rating of the
generator.

GFCI Receptacle Option

1

120 V 20 A AC GFCI Recep-
tacles GFCI2 and GFCI3

GFCI2 and GFCI3 supply 60 Hz
single-phase power at weld/power
speed. Maximum output from
GFCI2 or GFCI3 is 2.4 kVA/kW.
Circuit breaker protection is the
same as standard receptacles.

If a ground fault is detected, the
GFCI Reset button pops out and
the circuit opens to disconnect the
faulty equipment. Check for
damaged tools, cords, plugs, etc.
connected to the receptacle. Press
button to reset receptacle and
resume operation.

.

At least once a month, run
engine at weld/power speed
and press Test button to verify
GFCI is working properly.

1

Advertising