1. routine maintenance, 20 h 25 h, 50 h – Hobart Welding Products CHAMPION OM-493 User Manual

Page 24: 100 h, 200 h, 500 h, 1000 h

Advertising
background image

OM-493 Page 20

SECTION 7 – MAINTENANCE

7-1.

Routine Maintenance

Follow the storage procedure in the engine owner’s manual if the unit will not be used for an
extended period.

Note

Recycle

engine

fluids.

Y

Stop engine before maintaining.

.

See Engine Manual and Maintenance Label. Ser-
vice more often if used in severe conditions.

*

To be done by Factory Authorized Service Agent.

Wipe up spills.

Check fluid levels.
See Section 4-2.

20 h

25 h

Check and clean
spark arrestor screen.
See Section 7-7.

Service air
cleaner wrapper
(foam element).
See Section 7-3.

50 h

Clean and
tighten weld
terminals.

Clean cooling system.
See Engine Manual.

100 h

Change oil. See
Section 7-5 and
maintenance label.

Change oil filter. See
Section 7-5 and
maintenance label.

Clean and
tighten battery
connections.

Service air clean-
er element. See
Section 7-3.

200 h

Replace
fuel filter.
See
Section
7-5.

Check
valve
clearance.*

Check
spark
plugs.

Replace
unreadable
labels.

500 h

Repair or
replace cracked
cables.

Service welding generator
brushes and slip rings. Service
more often in dirty conditions.*

1000 h

Blow out or
vacuum inside.
During heavy
service, clean
monthly.

OR

Clean crankcase
breather valve.

Remove cylinder
head deposits.*