OM-493 Page 17

SECTION 5 – OPERATING THE WELDING GENERATOR

5-1.

Front Panel Controls

Ref. ST-192 519-A

5

1

Engine Control Switch

Use switch to start engine, select speed, and
stop engine. In Run/Idle position, engine runs
at idle speed at no load, and weld/power
speed under load. In Run position, engine
runs at weld/power speed.

2

Engine Choke Control

Use control to change engine air-fuel mix.

To Start: pull out choke and turn Engine Con-
trol switch to Start position. Release switch

and slowly push choke in when engine starts.
Do not crank engine if engine is still turning.

To Stop: turn Engine Control switch to Off
position.

3

Engine Hour Meter (Optional)

4

Coarse Adjust Switch

Y

Do not switch under load.

Use switch to select weld amperage range.
Place switch in Off position to stop output to
weld terminals.

.

For best arc starts, use lowest amperage
range possible.

5

Fine Adjust Control

Use control to select weld amperage within
the range selected by the Coarse Adjust
switch. Control may be adjusted while wel-
ding. Weld output would be 110 A DC based
on control settings shown (50% of 70 to 150
A). Set control at 10 for maximum auxiliary
power.

1

3

4

2