HP 377707-002 User Manual

Page 28

Advertising
background image

20

Operational State field

Displays the general condition of the interface card. The general
condition may appear as any of the following:

unknown

normal

wrong-image

bootFailed

tooHot

booting

A condition of unknown indicates an unsupported interface
card. To address this condition, replace the card with a
supported card.
The operational state of a card must appear as normal for the
current status of the card to appear as up.
A wrong-image condition indicates that the active system
image on the interface card does not match the active system
image on the controller. All cards must run the same active
system image as the controller card to function.
A bootFailed condition indicates that the active system image
on the card was incompletely or incorrectly loaded. If the other
interface cards come up successfully, reset the individual card.
Otherwise, reboot your entire device.
When your card overheats, the tooHot condition appears in the
show card command output. Enter the show fan command to
check to see if your fans failed.
The booting condition indicates that the card has not finished
loading necessary image data for internal configuration.

Boot Stage field

Boot Stage appears as one of the following:

recovery

ipl

ppcboot

fpga

pic

ib

rootfs

kernel

exe

done

none

Table 3-2: Card Properties Window Elements (Continued)

Element

Description

Advertising