Viewing Subnet Manager Properties

To view SM properties:
1. Expand the InfiniBand icon in the Tree frame.
2. Click the Subnet Managers branch. The Subnet Managers table appears in the View frame.
3. Click the radio button next to the SM that you want to view, then click the Properties button. The

Subnet Manager Properties window opens.

Table 5-2

lists and describes the elements in this

window.

Adding a Subnet Manager

To add a SM:
1. Expand the InfiniBand icon in the Tree frame.
2. Click the Subnet Managers branch. The Subnet Managers table appears in the View frame.
3. Click the Add button. The Add Subnet Manager window opens.
4. Enter a subnet prefix in the Subnet Prefix field.
5. Assign a priority value (integer) in the Priority field. The higher the integer, the higher the priority.
6. (Optional) Enter a key in the SM Key field.
7. Click the Apply button.

Table 5-2: Subnet Manager Properties Window Elements

Element

Description

Subnet Prefix field

Displays the subnet prefix of the SM.

GUID field

Displays the GUID of the networking device on which the SM runs.

Status field

Status of the SM. It may be active or inactive. If active, it is actively
managing subnets. If inactive, it is not managing subnets.

Activity Count field

Activity counter that increments each time the SM issues an subnet
management packet (SMP) or performs other management activities.

SM Key field

64-bit subnet management key assigned to the SM.The default is
fe:80:00:00:00:00:00:00. The SM key serves as the prefix of all GIDs
and “brands” nodes as members of this subnet.

Priority field

Priority of the SM relative to other SMs in the IB network. The lower
the number, the greater the priority.

Sweep Interval field

Specifies how frequently the SM queries the IB fabric for network
changes.

Response Timeout field Maximum amount of time that the SM waits for a response after it

sends a packet to a port. If the SM does not receive a response in time,
the SM identifies the port as unresponsive.

Apply button

Applies the changes that you make in the Subnet Manager Properties
window to the SM.

Reset button

Resets the fields in the window to match the properties of the SM.

Close button

Closes the Subnet Manager Properties window. If you close the
window before you apply changes, CM makes no changes to the SM.

Help button

Opens on-line help.