Viewing fibre channel target properties, Configuring fibre channel target properties – HP 377707-002 User Manual

Page 82

Advertising
background image

74

Viewing Fibre Channel Target Properties

To view the properties of a Fibre Channel target:
1. Expand the Fibre Channel icon in the Tree frame.
2. Click the Targets branch. A Targets table that includes all targets in your configuration file

appears in the View frame.

3. Click the radio button next to the target whose properties you want to view, then click the

Properties button. The SRP Target Properties window opens.

Table 7-5

lists and describes the

elements of this window.

Configuring Fibre Channel Target Properties

To configure the properties of a FB target:
1. Expand the Fibre Channel icon in the Tree frame.
2. Click the Targets branch. A Targets table that includes all targets in your configuration file

appears in the View frame.

3. Click the radio button next to the target whose properties you want to view, then click the

Properties button. The SRP Target Properties window opens.

4. (Optional) Click the down radio button or nlPort radio button to configure the connection type of

the target.

5. (Optional) Enter a description in the Description field.

Table 7-5: SRP Target Properties Window Elements

Element

Description

WWPN field

WWPN of the port on the target through which your Server Switch
accesses the target.

WWNN field

WWNN of the target.

FC Address field

FC address of the target.

IOC GUID field

InfiniBand I/O controller (IOC) through which initiators access the
target.

Physical Access
field

Port on your Server Switch (in slot#/card# format) through which your
Server Switch accesses the target.

MTU field

Maximum transmission unit, in bytes, of the target.

Connection Type
field

Provides the down and nlPort radio buttons so you can assign a
connection type to the target.

Description field

User-assigned target description.

NOTE: If no user has assigned a description, a default description
appears.

Service Name field Name of the service to associate with the WWPN.

Apply button

Applies the changes that you make in the window.

Reset button

Resets the fields in the window to match the properties of the target.

Close button

Closes the window. If you close the window before you apply changes,
CM makes no changes to the target.

Help button

Opens on-line help.

Advertising