Warning, Electrical connection – Hoshizaki KM-1601SWH/3 User Manual

Page 21

Advertising
background image

21

Fig. 8b

Fig. 8a

KM-1601SAH
KM-1601SWH
KM-1601SRH

KM-1601SAH3
KM-1601SWH3
KM-1601SRH3

• On single phase models, the white lead must be connected to the neutral conductor of

the power source.

CAUTION! Miswiring may result in severe damage to the icemaker.

See Fig. 8a.

• On three phase models, the transformer’s voltage tap switch must be positioned to match

incoming voltage at startup. See Fig. 8b.

CAUTION! On three phase models, connect the highest incoming voltage supply

("stinger leg") to the red power supply wire (red common wire to the compressor).

• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.

 WARNING

ELECTRICAL CONNECTION

THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage
to the icemaker. The white lead
must be connected to the neutral
conductor of the power source.
See diagram below.

4A4801-010

208-230/60/1

(3 wire with neutral for 115V)

JUNCTION BOX

208-230

V

BROWN

BLACK

L1

L2

WHITE

N

115- 120V

 WARNING

ELECTRICAL CONNECTION

THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage to
the icemaker.
This unit must be connected to a
three-phase power source.
The transformer’s voltage tap switch
must be positioned to match incoming
voltage at startup.
See diagram below.

208-230/60/3

4A4807-010

JUNCTION BOX

208-230

V

BROWN

BLACK

L1

L3

RED

L2

208- 230V

208- 230V