Hoshizaki KM-1601SWH/3 User Manual

Page 38

Advertising
background image

38

5) Attach a compressed air or carbon dioxide supply to the icemaker water supply line

drain valve.

6) Move the control switch to the "ICE" position.
7) Replace the front panel in its correct position, then turn on the power supply.
8) Blow the icemaker water supply line out using the compressed air or carbon dioxide

supply.

9) Close the icemaker water supply line drain valve.

2. Drain the water tank:

1) Turn off the power supply, then remove the front panel. Move the control switch to the

"OFF" position.

2) Remove the insulation panel. Remove the cap located on the front bottom part of the ice

dropping hole. See Fig. 20. Allow the water tank to drain.

3) Replace the cap and the insulation panel in their correct positions. Be careful not to

cross thread the cap.

4) Remove all ice from the storage bin. Clean the storage bin using a neutral cleaner.

Rinse thoroughly after cleaning.

5) Replace the front panel in its correct position.

3. On water-cooled model only, first remove the water from the water-cooled

condenser:

1) Make sure the power supply is off, then remove the front panel and right side panel.
2) Close the condenser water supply line shut-off valve. If connected to a closed loop

system, also close the condenser return line shut-off valve.

3) Open the condenser water supply line drain valve. If connected to a closed loop system,

also open the condenser return line drain valve.

4) Attach a compressed air or carbon dioxide supply to the condenser water supply line

drain valve.

5) Open the water regulating valve by using a screwdriver to pry up on the spring retainer

underneath the spring. While holding the valve open, blow out the condenser using the
compressed air or carbon dioxide supply until water stops coming out.

6) Close the drain valve(s).
7) Replace the right side panel and front panel in their correct positions.

Advertising