2. Water-Cooled Condenser

a) Connection to an Open Drain System
• Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" nominal

ID copper water tubing or equivalent is required for the condenser water supply line.

• A condenser water supply line shut-off valve and drain valve should be installed.
• Condenser drain outlet is 3/8" FPT. A minimum of 3/8" nominal ID hard pipe or equivalent

is required for the condenser drain line.

• In some areas, a back flow preventer may be required in the cooling water circuit.
• In order to maintain the proper high side pressure, the condenser water supply inlet

temperature should not drop below 45°F (7°C) and the condenser drain outlet temperature
must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker installation
is complete, confirm the condenser drain outlet temperature 5 minutes after a freeze
cycle starts. If the condenser drain outlet temperature is not in the proper range, use a
flat blade screwdriver to rotate the adjustment screw on the water-regulating valve until
the temperature is in the proper range (rotate counterclockwise to raise temperature or
clockwise to lower temperature).

Fig. 18

KM-16010SWH/3

Connection to an Open Drain System

Separate piping to approved drain.

Leave a 2-inch (5-cm) vertical air

gap between the end of each pipe

and the drain.

Icemaker Water Supply

Line Shut-Off Valve

Icemaker Water Supply

Line Drain Valve

Icemaker

Icemaker

Water Supply

Inlet

1/2" FPT

Bin Drain Outlet

3/4" FPT

2-inch (5-cm) air gap

Floor Drain

Icemaker

Drain Outlet

3/4" FPT

Bin

Condenser Water Supply

Line Shut-Off Valve

Condenser Water Supply

Line Drain Valve

Condenser Water

Supply Inlet

1/2" FPT

Condenser

Drain Outlet

3/8" FPT

Vent Tube

Vent Tube

Minimum 3/8" Nominal ID

Copper Water Tubing

Minimum 3/4" Nominal

ID Hard Pipe

Minimum 3/8"

Nominal ID

Hard Pipe

Condensation

Drain Outlet

3/8" OD Hard Tube

Vent Tube

Minimum 3/8" Nominal ID

Copper Water Tubing

Minimum 3/8"

Nominal ID

Hard Pipe