Icemaker – Hoshizaki KM-1601SWH/3 User Manual

Page 29

Advertising
background image

29

1. Icemaker
• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" nominal

ID copper water tubing or equivalent is required for the icemaker water supply line.

• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" nominal ID hard pipe or equivalent

is required for the icemaker drain line. Condensation drain outlet is 3/8" OD hard tube.
The condensation drain line can be connected to the icemaker drain line or can be run
separately.

KM-1601SAH/3
KM-1601SRH/3

Fig. 17

Remote Condenser

Line Set Connections

Separate piping to approved drain.

Leave a 2-inch (5-cm) vertical air

gap between the end of each pipe

and the drain.

Icemaker Water Supply

Line Shut-Off Valve

Icemaker Water Supply

Line Drain Valve

Icemaker

Icemaker Water

Supply Inlet

1/2" FPT

Bin Drain Outlet

3/4" FPT

2-inch (5-cm) air gap

Floor Drain

Icemaker

Drain Outlet

3/4" FPT

Bin

Vent Tube

Minimum 3/8" Nominal ID

Copper Water Tubing

Minimum 3/4"

Nominal ID Hard Pipe

Condensation

Drain Outlet

3/8" OD Hard Tube

Vent Tube