Stacking condenser unit, Fig. 15, Fig. 16 – Hoshizaki KM-1601SWH/3 User Manual

Page 27

Advertising
background image

27

1) Remove the louver panel. See Fig. 15.
2) Remove the junction box cover on the remote condenser unit. Remove the fan motor

junction box cover on the icemaker.

3) Install a ground wire from the icemaker to the remote condenser unit. Use wire of an

appropriate gage and outdoor rating.

4) Install line and neutral wires from the fan motor leads in the icemaker to the leads in

the remote condenser unit junction box. Use wire of an appropriate gage and outdoor
rating.

5) Replace the junction box covers and the louver panel in their correct positions.

7. Stacking Condenser Unit

1) Install the lower remote condenser unit as described earlier in this section.
2) Place the upper remote condenser unit on top of the lower. See Fig. 16.
3) Secure the upper remote condenser unit to the lower remote condenser unit with the

4 screws provided.

4) Install refrigerant lines and make electrical connection as described earlier in this

section.

Fig. 15

Screws

Louver Panel

Junction Box
Cover

Remote Condenser Unit

Icemaker

Screw

Fan Motor Junction
Box Cover

Fig. 16

Upper Remote
Condenser Unit

Screws

Lower Remote
Condenser Unit

Screws

Advertising