3. PLOTTER OPERATION

3-50

3.11.2 Arrival alarm

The arrival alarm informs you that your boat is approaching a destination waypoint. The
area that defines an arrival zone is that of a circle which you approach from the outside of
the circle. The alarm will be released if your boat enters the circle. When the arrival alarm is
active a red dashed circle marks the arrival alarm area. Note that the arrival alarm and
anchor watch alarm can be turned on together.

: Alarm area

Own ship

Alarm
range

Destination
waypoint

How the arrival alarm works

1. Press the ALARM key to open the alarm menu.
2. Use the Cursor pad to select ARRIVAL ALARM.
3. Press the EDIT soft key to show the arrival alarm window.

ARRIVAL ALARM

¡

ON 0.010nm

¤

OFF

Arrival alarm window

4. Use the Cursor pad to select ON.
5. Use the Cursor pad and the ENTER knob to enter alarm setting: Operate the Cursor

pad

to select digit; use the ENTER knob to enter value. The available arrival alarm

setting is 0.001 to 9.999 miles.

6. Press the ENTER soft key or push the ENTER knob to register setting.
7. Press the ALARM key to finish.