7. CUSTOMIZING YOUR UNIT

7-19

SAFETY STATUS indication

NORMAL

BEST MAP

DATA OFF DE-CLUTTER DANGER

CHART CONFIGURATION menu description (con’t from previous page)

Object Content

Setting

Description

ON Mixing

is

active.

MIXING

Changes chart scale to fit whole
chart on display

OFF Mixing

is

disabled.

LOCK

Keeps current chart scale.

CHART LEVEL

Maintains current chart scale
regardless of zoom setting

UNLOCK

Chart scale may chosen freely.

PLOTTER/
OVERLAY

Value-added data shown on plotter
and overlay displays.

PLOTTER

Value-added data shown on plotter
display.

VALUE-
ADDED DATA

Show/hide the "Conservation
Area" for *Australian waters.
(*Contact Australian authorities
for details.)

OFF

Value-added data is disabled.

PLOTTER/
OVERLAY

Camera icon shown on plotter and
overlay displays.

PLOTTER

Camera icon shown on plotter
display.

CAMERA ICON Show/hide camera icon, which is

used to display an image from
icon location. To display an
image, choose camera icon ( ),
push the ENTER knob and then
press the IMAGE soft key.

OFF

Camera icon is disabled.


*

1

SAFETY STATUS INDICATION

The following indications are shown beneath the range indication to denote safety status:

NORMAL (or U.ZOOM or O.ZOOM):
This indication appears to help you select a suitable
chart scale.
NORMAL: Suitable chart scale is selected.
U.ZOOM: Chart scale is too small.
O.ZOOM: Chart scale is too large.
BEST MAP: Shown in red when the unsuitable chart
scale is selected.
DATA OFF: Mixing levels can be turned on when the
electronics chart coverage area does not provide
enough coverage to completely fill the display screen.
When the cursor or own ship mark is placed in the
area with coverage, the chart data is shown as
below.
On: The chart line in the area with no coverage is
shown. This area is filled with dots.
Off: The area with no coverage is not shown (goes to
white).

DECLUT.: For C-MAP MAX charts, symbols of low priority (ex. map symbols on land)
can be automatically hidden to unclutter the screen when you change the scale. When
the function is turned on, DECLUT. appears in red.
DANGERS: Shown in red when the GROUNDING alarm detects the high-risk object
(listed in the grounding report) when the GROUNDING alarm is turned on.
CAUTIONS: Shown in red when the GROUNDING alarm detects the low-risk object
when the GROUNDING alarm is turned on.