Caution – Furuno NAVNET 1724C User Manual

Page 66

Advertising
background image

2. RADAR OPERATION

2-35

2.25.8 CPA/TCPA alarm (ARP)

When the predicted CPA of any target becomes smaller than a preset CPA alarm range or
its predicted TCPA less than a preset TCPA alarm limit, an audio alarm sounds and the
speaker icon appears (in red). In addition, the target plot symbol of the offending target
changes to a triangle and flashes together with its vector. You may silence the audio alarm
with the CLEAR key. Press the ALARM key and the message “COLLISION ALARM”
appears. Press the CLEAR ALARM soft key to acknowledge the alarm. The flashing of the
triangle plot symbol continues until you intentionally terminate tracking of the target. The
ARP continuously monitors the predicted range at the Closest Point of Approach (CPA) and
predicted time to CPA (TCPA) of each track to own ship.

This feature helps alert you to targets which may be on a collision course with own ship.
However, it is important that gain, A/C SEA, A/C RAIN and other radar controls are properly
adjusted and the ARP is set up so that it can track targets effectively.

CPA/TCPA alarm ranges must be set up properly taking into consideration the size,
tonnage, speed, turning performance and other characteristics of own ship.

CAUTION

The CPA/TCPA alarm should never be

relied upon as the sole means for detect-

ing the risk of collision. The navigator is

not relieved of the responsibility to keep

visual lookout for avoiding collisions,

whether or not the radar or other plotting

aid is in use.

Follow the steps shown below to set the CPA/TCPA alarm
range:

1. Press the MENU key followed by the ARP SETUP soft

key.

2. Operate the Cursor pad to select CPA.
3. Press the EDIT soft key to show the CPA window.
4. Select a CPA limit desired from 0.5 nm, 1 nm, 2 nm, 3

nm, 5 nm and 6 nm with the Cursor pad.

5. Press the ENTER soft key. The ARP SETUP menu

reappears.

6. Operate the Cursor pad to select TCPA.
7. Press the EDIT soft key to show the TCPA window.
8. Select a TCPA limit from 30 sec, 1 min, 2 min, 3 min, 4

min, 5 min, 6 min and 12 min.

9. Press the ENTER soft key.
10. Press the MENU key to close the menu.

CPA

¡

¡

¡

¡

¡

¡

¤

OFF

0.5nm

1nm

2nm

3nm

5nm

6nm

CPA distance

TCPA

¡

¡

¡

¡

¡

¡

¡

¤

30 seconds

1 minute

2 minutes

3 minutes

4 minutes

5 minutes

6 minutes

12 minutes

TCPA time

Advertising
This manual is related to the following products: