7 setting functions (functions menu), 1 functions menu description – Furuno NX-300 User Manual

Page 27

Advertising
background image

2-5

2.7

Setting Functions (FUNCTIONS menu)

See menu description below for detailed information.

1.

Press the [MENU] key to open the main menu.

2.

Press

! or " to select FUNCTIONS.

3.

Press the [ENT] key to display the FUNCTIONS menu.

Figure 2-14 FUNCTIONS menu

4.

Press

! or " to select menu item and press the [ENT] key.

5.

Press

! or " to select option desired.

6.

Press the [ENT] key to register your selection.

7.

Press the [MENU] key twice to close the menu.

2.7.1

FUNCTIONS menu description

RCV NOTIFY: The raw NAVTEX signal can be monitored through the monitor speaker by turning

RCV NOTIFY on. The default setting is OFF.

RCV ALARM: The audible alarm may be generated when message type A, B, D or L is received.

The default setting is ON.

KEY BEEP: The equipment can emit a beep tone when a control is operated. The default setting

is ON.

ERROR RATE: When character error occurs due to noise interference during signal propagation,

erroneous character is displayed as “

”.

Error Rate means character error rate and is calculated as followed:

Error Rate = number of erroneous characters

÷

total number of characters received

×

100 (%)

(Total number of characters includes space, line feed, carriage returns, etc.)

When the character error rate is within the percentage you set (0-39%), the NX-300 displays the

message and stores it. When it exceeds the percentage you set, the NX-300 neither displays nor

stores the message. You may set the threshold level of character error rate as desired and the