Resolving the unknown ribbon type error message, In s – FARGO electronic DTC500 User Manual

Page 104

Advertising
background image

RESTRICTED USE ONLY

Fargo Electronics, Inc.

DTC500 Series Card Printer/Encoders User Guide (Rev. 5.0)

104

Resolving the Unknown Ribbon Type Error Message

Symptom: The Printer is unable to determine the type of Ribbon installed.

Step

Procedure

1

Verify the Ribbon type.

a. Ensure that the print Ribbon installed in the Printer is a DTC Ribbon.

(Note: Although similar in appearance, an HDP Ribbon installed in a DTC
Printer will produce an Unknown Ribbon Type error message.)

2

Test the Ribbon Sensor (840108).

a. Remove the back cover and locate the connector labeled J16 on the main

board.

b. Check the voltage for each of the five (5) Ribbon Sensors at their

connection to the main board.

c. Use a Multimeter to ground the negative lead to the chassis and put the

positive lead on pins 3, 5, 7, 9 and 11 of J16 on the main board.

d. Place a RibbonTraq

mark over the Ribbon Sensor. (Note: The voltage

should be less than 1 VDC.)

e. Remove the RibbonTraq mark from the Ribbon Sensor. (Note: The

voltage should be greater than 4 VDC.)

f. Replace the Sensor if the voltages are incorrect. See the Replacing the

Ribbon Sensor Array Assembly (840108) procedure in Section 5, page
Error! Bookmark not defined..

Advertising