Frymaster 45 User Manual

Page 15

Advertising
background image

MASTER JET SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 2: INSTALLATION INSTRUCTIONS

2-5

2.3 Pre-Connection Preparations (cont.)


DANGER

Do not attach an apron drain board to a single fryer. The fryer may become

unstable, tip over, and cause injury. The appliance area must be kept free and clear

of combustible materials at all times.



Level fryers equipped with legs by screwing out the legs approximately 1 inch, and then adjust them
so that the fryer is level and at the proper height in the exhaust hood. Frymaster recommends that the
minimum distance from the flue outlet to the bottom edge of the filter be 24 inches (600 mm) when
the appliance consumes more than 120,000 BTU per hour.

For fryers equipped with casters, there are no built-in leveling devices. The floor where the fryer
is to be installed must be level.


4. Test the fryer electrical system:

a. Plug the fryer electrical cord(s) into a grounded electrical receptacle.

b. Place the power switch in the ON position.

For fryers equipped with thermostat controls, verify that the power and heat lights are lit.

For fryers having computer or digital displays, verify that the display indicates

c. Place the fryer power switch in the OFF position. Verify that the power and heat lights are

out, or that the display is blank.


5. Refer to the data plate on the inside of the fryer door to verify that the fryer burner is configured

for the proper type of gas before connecting the gas line quick-disconnect device or piping from
the gas supply line.

Advertising