Frymaster 45 User Manual

Page 41

Advertising
background image

MASTER JET SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 5: PREVENTATIVE MAINTENANCE

5-5

5.1 Fryer Preventive Maintenance Checks and Services (cont.)


4. Reinstall tube and bend it so that the opening is pointing downward.


SEMI-ANNUAL CHECKS AND SERVICES

Check Burner Manifold Pressure

DANGER

This task should be performed by qualified service personnel only. Contact FASC to

arrange this service.


5.2 Filter Magic II Filtration System Preventive Maintenance Checks and

Services

WARNING

Do not run water or boil-out solution through the filtration system. Doing so will

cause irreparable damage to the pump, and the warranty will be voided.


There are no periodic preventive maintenance checks and services required for your Filter Magic II
Filtration System other than daily cleaning of the filter pan (inner and outer filter pans on CF
systems) with a solution of hot water and detergent. Always remove the filter pan assembly from
the fryer before cleaning with hot water and detergent. After rinsing, turn the filter pan
upside down and slightly elevate the end to allow all water to drain from the suction tube.
Ensure the pan is dried thoroughly before returning to service.

If you notice that the system is pumping slowly or not at all, verify that the filter pan screen is on the
bottom of the filter pan, with the paper on top of the screen. If the filter screen and paper are
correctly installed, change the filter paper and verify that the O-rings on the connection fitting
(located inside the cabinet at the back) are present and in good condition. NOTE: With fresh paper
and properly installed O-rings, the system should refill the fryer in 2 to 3 minutes.

Immediately after each use, drain the Power Shower completely. If you suspect blockage, unscrew
the clean-out plugs at each corner of the frame. Place the frame in a pan of hot water for several
minutes to melt any accumulation of solidified oil/shortening. Use a long, narrow bottlebrush with
hot water and detergent to clean inside the tubes. If necessary, insert a straightened paper clip or
similar instrument into the holes in the frame to remove any blockages. Rinse, dry thoroughly, and
reinstall the plugs before using.

DANGER

Failure to reinstall the Power Shower cleanout plugs will allow hot oil to spray out of

the frypot during the filtering process, creating a burn hazard to personnel.