Depth, Space requirements, Room ventilation – Farallon Communications QMS 4525 User Manual

Page 139: Room volume, Acoustic noise emission

Advertising
background image

Physical
Specifications

B-7

Technical Specifications

„

With buffers 57.7" (1465 mm)

Depth

„

Without buffers 29.0" (735 mm)

„

With buffers 30.3" (770 mm)

Space Requirements

„

For operator: 24" (600 mm) at the front, on the right-hand and
the left-hand side

„

For service: 24" (600 mm) on all sides

„

Angle of inclination: Maximum of 4°

Room Ventilation

Recommended: Minimum of 438 cubic feet/hour (12.5 m

3

/h)

Room Volume

Recommended: Minimum of 855 cubic feet (25 m

3

)

With this room volume and the recommended room ventilation the
ozone emission is within the Threshold Limited Value for ozone (0.2
mg/m

3

).

2 &DXWLRQ)RUUHPRYDORIKHDWH[WUDYHQWLODWLRQPD\EHQHFHVVDU\

Acoustic Noise Emission

„

Stand-by: maximum 47 db (A)

„

Printing: maximum 64 db (A)

„

Impulse: maximum 73 db (A)

2 &DXWLRQ8VHRIFRQWUROVRUDGMXVWPHQWVRUSHUIRUPDQFHRISURFHGXUHVRWKHU

WKDQWKRVHVSHFLILHGKHUHLQPD\UHVXOWLQKD]DUGRXVUDGLDWLRQH[SRVXUH

Advertising