8-7

DATA 2 output setting

1) Press [MENU ESC] [9] and [4]. The

DATA 2 OUTPUT SETUP menu appears.

Figure 8-9 DATA 2 OUTPUT

SETUP menu

2) Follow the procedure for setting DATA 1

output.

DATA 3 output setting

The DATA 3 connector can output IEC 61162-
1/NMEA 0183 data or log pulse. (For details,
see the Installation Manual.) For NMEA 0183,
IEC 61162-1 the same data output by DATA
1 is output from DATA 3.

For log pulse, select 200 or 400 pulse per sec-
ond depending on the device connected.

1) Press [MENU ESC] [9] and [3].

2) Press ▲ or ▼ to select DATA 3. Log Pulse.

3) Press t or s to select log pulse of exter-

nal equipment; 200ppm or 400ppm.

4) Press the [NU/CU ENT] key twice.

Setting DATA 4 to NMEA

The DATA 4 port connects to a personal com-
puter, DGPS receiver or YEOMAN equip-
ment.

1) Press [MENU ESC] [9] and [5]. The

DATA 4 I/O SETUP (1/2) menu appears.

Figure 8-10 DATA 4 I/O SETUP menu (1/2)

2) Press ▲ or ▼ to select Level.

3) Press t or s to select level of external

equipment; RS232C or RS422.

4) Press the [NU/CU ENT] key.

5) Press t or s to select Out.

6) Press ▼ to select To Next Page. The DATA

4 I/O SETUP (2/2) menu appears.

Figure 8-11 DATA 4 I/O SETUP menu (2/2)

7) Follow "DATA 1 output setting" from step

2.

Talker ID GP LC DE

Output Data (00-90 sec)81%

DATA 2 OUTPUT SETUP

MENU : Escape

ENT : Enter

: Select

Settings shown here are default settings.

Data Fmt.

V1.5

V2.0

IEC

1. AAM:00 APA:00

APB:04 BOD:00

2. BWR:00 BWW:00 GGA:00

GLL:01

3. RMB:01 RMC:01 VTG:01

WCV:01

4. WNR:00 WPL:00 XTE:00

ZDA:01

5. GNS:00 ZTG:01

Rnn:00

RTE:00

To Previous Page

Talker ID GP LC DE

Output Data (00-90 sec) 81%

DATA 4 I/O SETUP <Out> 2/2

MENU : Escape

ENT : Enter

Data Fmt.

V1.5

V2.0

IEC

1. AAM:00 APA:00

APB:04 BOD:00

2. BWR:00 BWW:00 GGA:00

GLL:01

3. RMB:01 RMC:01 VTG:01

WCV:01

4. WNR:00 WPL:00 XTE:00

ZDA:01

5. GNS:00 ZTG:01

Rnn:00

RTE:00

DATA 4. Level RS232C RS422

Data Out Com. DGPS

To Next Page

DATA 4 I/O SETUP 1/2

MENU : Escape

ENT : Enter

: Select

Appears only when external
DGPS receiver is used.

DATA 4. Level

RS232C