Digital interface (iec 61162-1) – Furuno BACK GP-80 User Manual

Page 75

Advertising
background image

A-3

Digital Interface (IEC 61162-1)

Output sentences of channel 1, 2, 3, 4 (DATA 1, DATA 2, DATA 3, DATA 4)

AAM, APB, BOD, BWC, BWR, BWW, GGA, GLL, RMB, RMC, VTG, WCV, WNC, WPL,
XTE, ZDA, ZTG, RTE, DTM

Input sentences of channel 1 (DATA 1, DATA2, DATA4)

DBT, DPT, MTW, TLL

Transmission interval

All sentences output at the interval selected (00-90 s).

Load requirements as listener

Isolation: Optocoupler
Input impedance: 470 ohms
Max. voltage:

±

15V

Threshold: 3 mA (in case of connection of FURUNO device talker)

Data transmission

Data is transmitted in serial asynchronous form in accordance with the standard referenced in
2.1 of IEC 61162-1. The first bit is a start bit and is followed by data bits.

The following parameters are used:

Baud rate: 4800
Data bits: 8 (D7 = 0), parity none
Stop bits: 1

D0 D1 D2 D3 D4 D5 D6 D7

Start
bit

Stop
bit

Data bits