12 programming level one, 1 product selection – Frymaster 14 Series User Manual

Page 42

Advertising
background image

4-24

4.12 Programming Level One

Level one programming is used to enter new products, control when AIF (auto intermittent filtration)
is disallowed, and perform deep clean (boil- out) and high-limit tests.

To enter Level 1 programming mode:

1. With the computer

OFF, press the TEMP and INFO buttons

simultaneously (see Figure 97) for THREE seconds until

LEVEL 1 is

displayed; a chirp sounds.

Figure 97


The computer displays

ENTER Code and sounds an alert.

2. Enter 1234 (see Figure 98).

1

2

3

4

(1234)

Figure 98

The computer displays

level 1 program for three seconds changing to Product

selection.

3. Press the

t and

ubuttons (see Figure 99) to scroll between:

a.

Product selection See pg. 4-24

b.

aif clock See pg. 4-25

c.

DEEP CLEAN MODE See pg. 4-27

d.

high limit test See pg. 4-30

e.

Fryer setup See pg. 4-9

Figure 99

4. With the desired selection displayed, press the (1

yes) button to select

chosen menu item (see Figure 100).

Figure 100

4.12.1 PRODUCT SELECTION

1. To add or edit products in the product selection mode see pg. 4-12 ADDING A NEW

PRODUCT ITEM TO THE MENU Steps 4-30.

The submenus under product selection are:

a.

Name – Enter full product name limit eight characters (FR FRIES).

b.

cook time – Enter cook time (ex. 3:30 as 0330).

c.

temp – Enter cook temperature. (ex. 335° as 335).

d.

cook id – Enter four (4) letter product ID (ex. CPSY).

e.

qual tmr – Enter quality time for hold time (ex. 7:00).

f.

DUTY TIME 1 – Enter the seconds into the cook cycle that the first duty alarm

sounds. (ex. 30 seconds- to shake fries).
g.

DUTY TIME 2 – Enter the seconds into the cook cycle that a second duty alarm

sounds.
h.

aif disable – Enter YES if AIF is to be disabled for specific products.

i.

assign btn – Assigns menu items to a specific button for simplified cooking.

Advertising