Genie AWP 114002 User Manual

Page 19

Advertising
background image

Operator’s Manual

Third Edition • Fourth Printing

Part No. 114002

Genie AWP Super Series

17

12 Push in the red Emergency Stop button at the

platform controls to the off position.

13 Pull out the red Emergency Stop button at the

ground controls to the on position.

14 Push in the control activate button and rotate

the up/down switch in the direction of intended
travel.

Result: The up/down function should not

operate.

Test Outrigger Interlock

15 Twist to release the red Emergency Stop button

at the platform controls.

Result: The up/down functions should operate.

16 Unscrew one leveling jack until the

corresponding interlock display light turns off.

Result: The up function should not operate.

17 Return the leveling jack to the previous setting

and check the bubble level.

18 Repeat this procedure for each outrigger.

Test Auxiliary Platform Lowering
- AC & DC Models

19 Raise the platform slightly.

20 Disconnect the power source from the machine.

21 Turn the key switch to ground control.

22 Push in the auxiliary platform lowering button at

the ground controls.

Result: The platform should lower.

FUNCTION TESTS

23 Connect the power source to the machine.

24 Turn the key switch to platform control.

25 Raise the platform slightly.

26 Disconnect the power source from the machine.

27 Push in the control activate button and rotate

the up/down switch in the down direction.

Result: The platform should lower.

28 Connect the power source to the machine.

Test Manual Lowering

29 Raise the platform slightly.

30 Activate the manual

lowering valve located
at the bottom of the
hydraulic cylinder.

Result: The

platform should
lower.

Advertising