SAFETY RULES

Electrocution Hazards

This machine, even with an optional fiberglass
platform, is not electrically insulated and will not
provide protection from contact with or proximity to
electrical current.

Keep away from the machine if it contacts
energized power lines or becomes electrically
charged. Personnel on the ground or in the platform
must not touch or operate the machine until
energized power lines are shut off.

Maintain safe distances from electrical power lines
and apparatus in accordance with applicable
governmental regulations and the following chart.

Minimum Safe

Voltage

Approach Distance

Phase to Phase

Feet

Meters

0 to 300V

Avoid Contact

300V to 50KV

10

3.05

50KV to 200KV

15

4.60

200KV to 350KV

20

6.10

350KV to 500KV

25

7.62

500KV to 750KV

35

10.67

750KV to 1000KV

45

13.72

Allow for platform movement, electrical line sway
or sag and movement due to strong or gusty winds.

Do not use the machine as a ground for welding.

Do not operate an AC powered machine or a DC
battery charger unless using a 3-wire grounded
extension cord connected to a grounded AC circuit.
Do not alter or disable 3-wire grounded plugs.

Tip-over Hazards

Do not raise the platform unless the base is level,
all four outriggers are properly installed and the
leveling jacks firmly contact the floor.

Do not adjust or remove the outriggers while the
platform is occupied or raised.

Do not move the machine while the platform is
raised.

Do not place ladders or scaffolds in the platform or
against any part of this machine.

Do not place or attach overhanging loads to any
part of this machine.

Do not transport tools and materials unless they are
evenly distributed and can be safely handled by the
person in the platform.