STEP 4 MOUNT TEMPLATE

• Align the template with the marks on the ceiling and

tape in place.

– Be sure the template is oriented correctly, with the

front of the hood.

• Use a plumb bob to be sure the mounting holes will

provide parallel alignment with the countertop below.

• Center-punch all hole locations.
• Drill pilot holes in the 4 screw locations. Use a 5/32"

bit and drill approximately 1-1/2" deep.

• Cut the 8-1/4" duct opening and approximately 1" wire

access hole.

Installation Instructions

STEP 5 INSTALL SUPPORT FRAME

Install upper support frame
• Secure the upper support frame to the ceiling joists

and cross-framing with the 4 lag screws provided.
For maximum rigidity and strength, the screws must
be driven into the center of the joists and/or cross-
framing.

Check to be sure the support frame is level, vertically
and horizontally.

Install lower support frame
• Insert lower support frame (or accessory support

frame, ZX1059SFSS or ZX10510SFSS) into the upper
support frame and loosely secure with 8 screws and
washers (4 on the front and 4 on the back sides).

• Adjust the lower support frame up or down to the

desired height above the countertop. Tighten screws.

IMPORTANT: Again, check to be sure the support
is level in both directions. There is no way to level
the hood after the hood is secured to the frame.

538Dia19

30" Recommended

10"

40"

Countertop

Hood

Mounting

Flange

Lower Support

76"

538Dia31

Wire Access Holes