Circuit description, General details, When selecting cooking power level and time – Goldstar MA-2005ST User Manual

Page 22: When touching the start pad, When the oven is set at any level except maximum, When the door is opened during cooking

Advertising
background image

CIRCUIT DESCRIPTION

GENERAL DETAILS

¥ The low voltage transformer supplies the necessary

voltage to the micom controller when power cord is
plugged in.

¥ When the door is closed, the primary switch is ON, the

secondary switch is ON, and the monitor switch opens
(contact COM and NO).

WHEN SELECTING COOKING POWER
LEVEL AND TIME

¥ The micom controller memorizes the function you set.
¥ The time you set appears in the display window.
¥ Each indicator light turns on to indicate that the stage

has been set.

WHEN TOUCHING THE START PAD

¥ The coil of the relay is energized by the micom

controller.

¥ Power input is supplied to the high voltage transformer

through the fuse to the primary switch and relay 2.

¥ Turntable rotates.

¥ The fan motor rotates and cools the magnetron by

blowing the air (coming from the intake on the base-
plate).

¥ The air is also directed into the oven to exhaust the

vapor in the oven through the upper plate.

¥ Cooking time starts counting down.
¥ 3.3 volts AC is generated from the filament winding of

the high voltage transformer. This 3.3 volts is applied to
the magnetron to heat the magnetron filament through
two noise-preventing choke coils.

¥ A high voltage of approximately 2100 volts AC is

generated in the secondary of the high voltage
transformer which is increased by the action of the high
voltage diode and charging of the high voltage
capacitor.

¥ The negative 4,000 Volts DC is applied to the filament

of the magnetron.

WHEN THE OVEN IS SET AT ANY LEVEL
EXCEPT MAXIMUM.

¥ The micom controller controls the ON-OFF time of

relay 2 by the applied signal to vary the average output
power of microwave oven as POWER LEVEL.
(refer to page 1-1)

¥ One complete cycle of relay 2 is 22 seconds.

WHEN THE DOOR IS OPENED DURING
COOKING

¥ Both the primary switch and relay 2 cut off the primary

winding voltage of the high voltage transformer.

¥ ON-OFF of relay 2 is coupled electrically with opening

and closing of the secondary switch.

¥ When the door is opened, the secondary switch is

opened and when the door is closed, the secondary
switch is closed.

¥ The cooking time stops counting down.
¥ Relay stops functioning.
¥ As the door is opened, if the contact of primary switch

and relay2 and/or secondary switch fail to open, the
fuse opens due to the large current surge caused by
the monitor switch activation, which in turn stops
magnetron oscillation.

4-4

L

FUSE

H.V.

TRANS-

FORMER

RELAY 2

MICOM CONTROLLER

SECONDARY
SWITCH

PRIMARY

SWITCH

MONITOR

SWITCH

N

L

FUSE

RELAY 2

MICOM CONTROLLER

SECONDARY
SWITCH

PRIMARY

SWITCH

MONITOR

SWITCH

H.V.

TRANS-

FORMER

N