Condition check result cause remedy – Goldstar MA-2005ST User Manual

Page 37

Advertising
background image

5-15

CONDITION

CHECK

RESULT

CAUSE

REMEDY

No microwave
oscillation.

No continuity.

Continuity.

Abnormal

Defective high
voltage
transformer.

Replace high
voltage
transformer.

Normal

Defective PCB
assembly.

Replace PCB
assembly.

Disconnect the
wire leads from
relay 2 and
check continuity
of relay 2.
(Operate the unit)

Check high vol-
tage transformer

Output is full power
when you set lower
power level.

Abnormal.

Defective PCB
assembly.

Replace PCB
assembly.

Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)

Abnormal

Defective high
voltage capacitor.

Replace high
voltage capacitor.

Normal

Check high vol-
tage capacitor.

Abnormal

Defective high
voltage diode.

Replace high
voltage diode.

Normal

Check high vol-
tage diode.

Abnormal

Defective
magnetron.

Replace
magnetron.

Check
magnetron.

(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.

(Display operates properly)

NOTE : ¥ Make sure the wire leads correct position.

¥ When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
¥ When removing the magnetron, be sure to install the magnetron gasket in the correct position

and in good condition.