D. PCB ASSEMBLY REMOVAL

1) Remove the control panel assembly from the

cavity. (Refer to control panel assembly removal
on previous page.)

2) Remove screws which hold the PCB SUB ASSÕY to

the control panel.

3) Disconnect the flat cable from the PCB SUB

ASSÕY and take off the PCB SUB ASSÕY

E. DOOR MAIN ASSEMBLY REMOVAL

1) Open the door.
2) Remove the choke cover very carefully with a flat-blade

screwdriver.

CAUTION: Be careful not to damage door seal plate

by screwdriver.

3) Lift up and push the door.

NOTE:
1. After replacing the door, be sure to check that the

primary switch, monitor switch, and secondary switch
operate normally.

2. After replacing the door, check for microwave energy

leakage with a survey meter. Microwave energy must
be below the limit of 4 mW/cm. (with a 275 ml water
load)

3. When mounting the door assembly to the oven

assembly, be sure to adjust the door assembly parallel
to the chassis. Also adjust so the door has no play
between the inner door surface and oven frame
assembly. If the door assembly is not mounted
properly, microwaves may leak from the clearance
between the door and the oven.

5-4

Key Membrane

Door Open Button Release

Lever

Button Spring

Control Panel

PCB Sub Asm

Remove door

Remove choke cover

Spacer