COMPONENTS

TEST PROCEDURE

RESULTS

RELAY 2

FAN MOTOR
(Wire leads removed)

TURNTABLE
MOTOR
(Wire leads removed)

Check for continuity of relay 2 with an
ohm-meter.
(Remove wire leads from relay 2 and
operate the unit.)

Measure the resistance.
(Ohm-meter scale: R x 1)

Measure the resistance.
(Ohm-meter scale: R x 1 )

POWER
LEVEL

1

4 sec

18 sec

2

6 sec

16 sec

3

8 sec

14 sec

4

10 sec

12 sec

5

12 sec

10 sec

6

14 sec

8 sec

7

16 sec

6 sec

8

18 sec

4 sec

9

20 sec

2 sec

10

22 sec

0 sec

Normal:
A: Approx. 85 ~ 100 ohm.
B: Approx. 10 ~ 25 ohm.

Abnormal: Infinite or several

ohm.

Normal: Approx.100~150 ohm
Abnormal: Infinite or several

ohm.

NOTE : ¥ A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS

SERVICED FOR ANY REASON.

¥ MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
¥ WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE

CONNECTOR, NOT THE WIRES.