Component test procedure, Cautions, Components test procedure results – Goldstar MA-2005ST User Manual

Page 30

Advertising
background image

5-8

CAUTIONS

1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE

OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)

2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER

OF WATER IN CONTAINER) IN THE OVEN.

COMPONENTS

TEST PROCEDURE

RESULTS

HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)

MAGNETRON
(Wire leads removed)

1. Measure the resistance.

(Ohm-meter scale: Rx1 and Rx100)
¥ Primary winding
¥ Secondary winding
¥ Filament winding

2. Measure the resistance.

(Ohm-meter scale: Rx1000)
¥ Primary winding to ground
¥ Filament winding to ground

1. Measure the resistance.

(Ohm-meter scale: Rx1)
¥ Filament terminal

2. Measure the resistance.

(Ohm-meter scale: Rx1000)
¥ Filament to chassis

Approx.: 0.2 ~ 0.4 ohm
Approx.: 60 ~ 90 ohm
Less than: 1 ohm

Normal: Infinite
Normal: Infinite

Normal: Less than 1 ohm

Normal: Infinite

PRIMARY
TERMINAL

SECONDARY

FILAMENT
WINDING

COMPONENT TEST PROCEDURE

Advertising