F. AIR DUCT ASSEMBLY REMOVAL

1) Disconnect the leadwire from the lamp.

2) Remove the mounting screw to the magnetron.

G. MAGNETRON REMOVAL

1) Disconnect the leadwire from the magnetron.
2) Carefully remove the mounting screws holding the

magnetron and the waveguide.

3) Remove the magnetron ASSÕY until the tube is

clear from the waveguide.

NOTE:
1. When removing the magnetron, make sure its

dome does not hit any adjacent parts, or it may be
damaged.

2. When replacing the magnetron, be sure to install

the magnetron gasket in the correct position and
be sure that the gasket is in good condition.

3. After replacing the magnetron, check for microwave

leakage with a survey meter around the
magnetron. Microwave energy must be below the

limit of 5 mW/cm

2

. (With a 275 ml. water load).

Make sure that gasket is rigidly attached to the

magnetron. To prevent microwave leakage,
tighten the mounting screws properly, making sure
there is no gap between the waveguide and the
magnetron.

H. REMOVING THE TURNTABLE MOTOR

1) Remove the turntable and rotating ring.
2) Lay the unit down on its back.
3) Remove the turntable motor cover.

The turntable base cover is easily removed by

pinching the eight parts with a wire cutting.

4) Disconnect the leadwire from the turntable motor

terminals.

5) Remove the screw securing the turntable motor to

the oven cavity ASSÕY

6) After repairing the motor, rotate the removed

turntable motor cover.

7) Fit the turntable motor coverÕs projecting part to the

base plate slit.

NOTE:
1. Remove the wire lead from the turntable motor

VERY CAREFULLY.

2. Be sure to grasp the connector, not the wires, when

removing.

Waveguide

Magnetron

Air Duct

Magnetron
Gasket

Magnetron

Dome

Waveguide
Bracket

Wire Leads

Turntable Motor