Measurement of microwave power output, Disassembly and adjustment, A. outer case removal – Goldstar MA-2005ST User Manual

Page 25: B. power supply cord, C. control panel assembly

Advertising
background image

¥ Microwave power output measurement is made with

the microwave oven supplied at its rated voltage and
operated at its maximum microwave power setting with
a load of (1000±5) g of potable water.

¥ The water is contained in a cylindrical borosilicate glass

vessel having a maximum material thickness of 3 mm
and an outside diameter of approximately 190mm.

¥ The oven and the empty vessel are at ambient

temperature prior to the start of the test.

¥ The initial temperature (T1) of the water is (10±2)¡C It

is measured immediately before the water is added to
the vessel. After addition of the water to the vessel,
the load is immediately placed on the center of the
turntable which is in the lowest position and the
microwave power switched on.

¥ The time T for the temperature of the water to rise by a

value

Æ T of (10±2)¡K is measured, where T is the time

in seconds and ÆT is the temperature rise. The initial
and final water temperatures are selected so that the
maximum difference between the final water
temperature and the ambient temperature is 5¡K.

¥ The microwave power output P in watts is calculated

from the following formula :

4187 x (ÆT)

T

is measured while the microwave generator is

operating at full power. Magnetron filament heat-up
time is not included. (about 3 sec)

¥ The water is stirred to equalize temperature throughout

the vessel, prior to measuring the final water
temperature.

¥ Stirring devices and measuring instruments are

selected in order to minimize addition or removal of
heat.

A. OUTER CASE REMOVAL

1) Disconnect the power supply cord from the outlet.

2) Remove the screws from the rear of the case.

The outer case must be moved backward to be lifted
off.

B. POWER SUPPLY CORD

1) Remove the outer case.
2) Disconnect two terminals, and remove one screw of

the ground terminal.

C. CONTROL PANEL ASSEMBLY

1) Open the door.
2) Disconnect the leadwire from RELAY (RY2) of the

PCB SUB ASSÕY.

3) Disconnect the leadwire from connector (CN1) of the

PCB SUB ASSÕY.

4) Lift up and pull out control panel assembly carefully

from the cavity.

CAUTION: DISCHARGE THE HIGH VOLTAGE

CAPACITOR BEFORE SERVICING

(refer to page 2-1)

5-3

WATER LOAD

TURNTABLE

ground screw

MEASUREMENT OF MICROWAVE POWER OUTPUT

P =

Remove the screw

Lift up and pull out control panel

DISASSEMBLY AND ADJUSTMENT