Filters, Ducting – Grizzly 3HP Dry Spray Booth G0533 User Manual

Page 18

Advertising
background image

-16-

Model g0533 (Mfg. since 3/11)

2. Make sure the work table opens and closes

smoothly.

3. reach under the work table and fully extend

the two support legs.

4. lock the latches on the bottom of each cur-

tain into the work table.

2. install six second-stage filters above and

below the middle brace along the inner rails,
as shown in

figure 13.

filters

To install the filters:

1. Install the six third stage filters into the filter

case as shown in

figure 12.

figure 14. First stage filters.

figure 13. second-stage filters.

3. Install six first stage filters (figure 14) along

the outer rails.

Ducting

the g0533 dry spray booth must be vented to
the outside of your shop or building using 12"
metal spiral wound ducting or 18 gauge rolled
galvanized steel ducts in accordance with nFpa
33 guidelines.

figure 12. third stage filters (only three shown).

Filter

Case

Middle

Brace

inner

rail

outer

rail

third stage

Filters

Advertising