6. With new filters installed, turn the spray booth

ON, observe the rise in the reading, and mark
with the supplied green arrow as shown in the
example in

figure 19.

7. Multiply the reading from Step 6 times 2 (2x)

and mark with the supplied red arrow (

figure

20). this is the dirty filter indicator mark.
When the fluid reaches the red arrow, install
new filters.

Note: Always make sure the fluid level is at
zero before using the spray booth each time.
Also, check the fluid level on a regular basis
and re-fill as needed.

figure 20. dirty filter mark example.

dirty Filter

indicator

Mark

figure 19. new filter installation mark example.

new Filter

indicator

Mark