Notice, Filter indicator – Grizzly 3HP Dry Spray Booth G0533 User Manual

Page 20

Advertising
background image

-18-

Model g0533 (Mfg. since 3/11)

SEcTiON 4: OPERATiONS

Damage to your eyes, lungs, and ears could

result from using this machine without

proper protective gear. Always wear safety

glasses, a respirator, and hearing protection

when operating this machine.

Loose hair and cloth-

ing could get caught in

machinery and cause seri-

ous personal injury. Keep

loose clothing and long

hair away from moving

machinery.

NOTICE

if you have never used this type of machine

or equipment before, WE STRONGLY REc-

OMMEND that you read books, trade maga-

zines, or get formal training before begin-

ning any projects. Regardless of the con-

tent in this section, Grizzly industrial will

not be held liable for accidents caused by

lack of training, neglect or misuse.

filter indicator

NOTicE: never operate the spray booth without
all of the air filters installed!

To fill the air filter indicator (manometer):

1. turn the spray booth OFF!

2. disConneCt the poWer!

3. Check to make sure the manometer body is

level. adjust as needed.

4. rotate the zero adjustment knob counter-

clockwise (

figure 18) until it stops, then turn

it clockwise three turns.

figure 18. air filter indicator controls.

plug

zero adjustment Knob

5. remove the plug (figure 18) and fill the

chamber with the included red gauge oil until
the fluid level reaches zero on the indicator.
Minor fluid level adjustments can be made
using the zero adjustment knob.

Note: only use dwyer

®

red gauge oil to fill

the manometer. if you need additional oil,
order grizzly part number p0533062.