Air filter indicator – Grizzly 3HP Dry Spray Booth G0533 User Manual
Page 19
![background image](/manuals/109362/19/background.png)
Model g0533 (Mfg. since 3/11)
-17-
Air filter indicator
To install the air filter indicator:
1. Mount the manometer to the side of the spray
booth by threading the M4 x 45 tap screws
into the pre-drilled holes (
figure 15).
2. Adjust the manometer so the built-in level
reads level (
figure 15).
3. install a tubing connector fitting in the larger
pre-drilled hole on the side of the booth near
the manometer as shown in
figure 16.
4. run tubing from the low pressure side (-) of
the manometer to the tubing connector fitting
as shown in
figure 16.
5. install tubing into the high pressure side (+) of
the manometer and secure it with the plastic
clip and an M4 x 12 tap screw as shown in
figure 17.
figure 16. tubing installed onto spray booth
chamber.
tubing
Connector
Fitting
figure 17. tubing secured with clip.
plastic
Clip
figure 15. Mounting manometer to spray booth.
Built-in
level