Air filter indicator

To install the air filter indicator:

1. Mount the manometer to the side of the spray

booth by threading the M4 x 45 tap screws
into the pre-drilled holes (

figure 15).

2. Adjust the manometer so the built-in level

reads level (

figure 15).

3. install a tubing connector fitting in the larger

pre-drilled hole on the side of the booth near
the manometer as shown in

figure 16.

4. run tubing from the low pressure side (-) of

the manometer to the tubing connector fitting
as shown in

figure 16.

5. install tubing into the high pressure side (+) of

the manometer and secure it with the plastic
clip and an M4 x 12 tap screw as shown in

figure 17.

figure 16. tubing installed onto spray booth

chamber.

tubing

Connector

Fitting

figure 17. tubing secured with clip.

plastic

Clip

figure 15. Mounting manometer to spray booth.