Site requirements, Minimum builders opening, Riva mf cassette – Stovax PM235 RV66AVC User Manual

Page 17: Builders opening

Advertising
background image

17

SITE REQUIREMENTS

4. MINIMUM BUILDERS OPENING

To make installation easier make the opening larger than

the minimum requirements where possible.

*see note

Riva 55/66/76 only

If optional convection air ducts are to be used, increase the

opening height by 300mm to enable connection to be made

before final completion of building work.

Riva 66/76 only

Dimension C may be reduced to 355mm when using the

spacer frame kit.

Consideration must be given for the clearance of 20mm

between the flue pipe and lintel/inside chimney breast

5. RIVA MF CASSETTE

Riva 40 Riva 55 Riva 66 Riva 66 Avanti Riva 76

RV40

RV55

RV66

RV66 AVC

RV76

A

410mm 550mm 660mm

660mm

770mm

B

560mm 670mm 560mm

560mm

640mm

C

360mm 360mm 405mm*

405mm*

405mm*

* Riva 66/76 only

Dimension C may be reduced to 355mm when using the spacer

frame kit.

For information on frames available, please contact your local
retailer or call Stovax Ltd on 01392 474011

Consideration must be given for the clearance of 20mm between

the flue pipe and lintel/inside chimney breast.

* In the U.K

Additional information covering the installation the

appliance may be found in the following British Standards:-

BS6461, BS6999, BS8303.

6. BUILDERS OPENING

Many fireplace openings have a supporting lintel. Remove

the covering plaster to identify it's position before starting

any constructive work. Do not remove constructional lintels

without making provision to support the remaining structure

of the building. The appliance must not form any part of the

supporting structure.

6.1 The chimney/flue must have a sealed connection to the

appliance flue spigot.

6.2 The structure of the builders opening will reach high

temperatures. Use insulating blockwork to reduce the heat

transfer to the external walls, in particular the area of the

chimney breast above the opening.

6.3 Take care when finishing the chimney breast and

surrounding area. The conducted and convected heat

emitted by the appliance could be high enough to crack

normal plaster. Use a high temperature plaster, or face

the area with a suitable high temperature plasterboard.

New plaster should be fully dried before the appliance is

used, or cracking could occur.

Riva 40 only

It is possible to fit the Riva 40 into an existing, traditional, 16”

fireplace opening following the removal of any existing milner

fireback. Following the removal of the fireback and any flaunching

above, the builders opening should be checked and made good to

the dimensions shown in the table. Care should be taken to ensure

the existing chimney is in good condition and that it is possible to

make the required sealed fluepipe connections to this when the

Riva 40 is installed.

If you are in any doubt about your ability to produce a safe

opening contact your Stovax dealer for professional advice.*

Riva 55/66/76 only

Should you wish to connect air ducting to the convection system,

provision should be made to increase the opening height by an

additional 300mm. This will allow the access needed to fit the

duct pipes after connecting the flue system.

Advertising
This manual is related to the following products: