User instructions, Riva, Riva avanti – Stovax PM235 RV66AVC User Manual

Page 6: Warning, Using the appliance for the first time, Recommended fuels

Advertising
background image

6

USER INSTRUCTIONS

1.16 Riva 66 Avanti

To open and close the door:

• Use the tool provided, see Diagram

Remove

Pull to open

RIVA

Lift to Open

Remove

RIVA AVANTI

PR7049

WARNING

Properly installed, operated and maintained this

appliance will not emit fumes into the room.


Occasional fumes from de-ashing and refuelling may occur.

Persistent fume emission is potentially dangerous and

must not be tolerated.

If fume emission does persist:

• Open doors and windows to ventilate the room

•Allow fire to burn out or safely dispose of fuel from the

appliance

• Leave the room

• Check for chimney blockage and clean if required

• Do not attempt to relight until the cause of the emission

has been identified and corrected

If necessary seek expert advice.

2. USING THE APPLIANCE FOR THE FIRST

TIME

2.1 To allow the appliance to settle and fixing glues and paint to

fully cure:

• Operate the appliance at a low output for first few days

2.2 Do not touch the paint during the first period of use.

2.3 During this time the appliance may give off some

unpleasant odours:

• Keep the room well ventilated to avoid a build-up of

fumes

3. RECOMMENDED FUELS

3.1 Wood Logs:

• Burn only seasoned timber with a moisture content of less

than 20%

Wood Length

Appliance

Wood Length

Riva 40

250mmm

Riva 55

350mm

Riva 66

450mm

Riva 66 Avanti

450mm

Riva 76

510mm

• Dry cut wood for 12 to 18 months before use

Poor quality timber:

— Causes low combustion efficiency

— Produces harmful condensation

— Reduces effectiveness of the airwash and life of the

appliance

Do not burn construction timber, painted, impregnated

/ treated wood, manufactured board products or pallet

wood

.