LEGAL REQUIREMENTS

Before installation of this product please read these

instructions fully.

It is very important to understand the requirements of the national

Building Regulations* and standards**, along with any local

regulations and working practices that may apply. Should any

conflict occur between these instructions and these regulations

then the regulations must apply.

Your local Building Control Office can advise regarding the

requirements of the regulations.

The appliance must be fitted by a registered installer†, or

approved by your local building control officer.

Works must be carried out with care to meet the requirements of

Health and Safety‡ and comply with the Health and Safety rules,

and any new regulations introduced during the lifetime of these

instructions.. Particular attention should be drawn to:

Handling: The appliance is heavy. Adequate facilities

must be available for loading, unloading and site handling.

Fire Cement: Some fire cement is caustic and must not

come into contact with the skin. Protective gloves must be

worn. Wash hands thoroughly with plenty of water after

contact with skin.

Asbestos: This appliance contains no asbestos. If there

is the possibility of disturbing any asbestos in the course of

installation seek specialist guidance and use appropriate

equipment.

Metal Parts: Take care when installing or servicing the

stove to avoid personal injury.

A faulty installation can cause danger to the inhabitants and

structure of the building.

For users of this appliance:

Your building insurance company may require you to inform them

that you have installed a new heating appliance. Check that your

cover is still valid after installing the appliance.

1. INSTALLING THE APPLIANCE

Each installation is unique to the property so it is not possible

to give details to suit every setting. The installation must comply

with Building Regulations and be made using "best practice"

construction methods.

Many fireplace openings have a supporting lintel. Do not remove

without supporting the remaining structure of the building. Do not

support the structure with the appliance or the flue system

.

1.1 Take care when installing the appliance. Careless

handling and use of tools can damage the finish and/or

area

.

1.2 To make the fitting of the Riva MF easier, gain better access

to the flue connection and protect paintwork from damage,

remove the internal components and the lower frame

fitting screws. The ashpit door, door and the front trim may

be removed on Riva products.

INSTALLATION INSTRUCTIONS

1.3 • Slide the Riva MF into the opening

(Riva Only) If the Riva MF is to be fiited with a 4 sided

frame, fit the frame before fixing the appliance in to

position.

(Riva Only) Check the fit of all frame options before fixing

the appliance into position

Some installations may require the frame to be fitted

before final fixing.

• Fix in place using the fixing holes located under the

ashpan, see diagram

• Fix using the kit provided

Tools required 10mm A/F spanner /socket wrench and

masonry drill)

PR7245

Securing Bolt Holes

1

• Ensure that the flange of the Riva MF is still flat against

the opening after tightening the fixing screws

1.4 Fill any void at the back or sides of the box with 6:1

vermiculite / cement mix or any other good quality non-

combustible insulation material. It is important that the

back and sides of the box are well insulated.

1.5 • Connect the flue liner and flue adaptor to the Riva MF by

inserting the flue spigot from the inside of the Riva MF

• Slide the flue pipe or liner adaptor inside the spigot

• Seal the flue to the spigot using fire cement

• Seal the spigot to the inside of the Riva MF using fire

cement. See diagrams 2, 3, 4.

In The U.k:

* England and Wales – Document J / Scotland - Part F/

Document J (Republic of Ireland only)

** In the U.K BS 8303, BS 6461, BS 7566

† registered body: HETAS (GB only)/INFO (Eire)

‡ Health and Safety at Work Act 1974