Installation instructions, Baffle removal (all) – Stovax PM235 RV66AVC User Manual

Page 23

Advertising
background image

23

INSTALLATION INSTRUCTIONS

5

• Remove the fixing screws and lift the ashpit door clear of
the appliance

4.2 The replacement of the system is the reverse of the

previous operations.

5. BAFFLE REMOVAL (ALL)

(Tools required – None)

The Riva MF is fitted with a twin baffle system, consisting of

upper and lower baffles, Diagram 6.

6

PR7017

Upper Baffle

Lower Baffle

5.1 Remove the log guard from the Riva MF to give access to

the firebox.

5.2 First remove the Lower Baffle, see diagram 7:

• Lift the front edge to unhook it from the support bars

• Pull the baffle forward to disengage the rear edge from

the location above air inlet holes

• Rotate the baffle to remove from the firebox through the

door opening

5.3 Second remove the Upper Baffle, see diagram 8:

• Pull forward to disengage it from the hanging points at the

top of the firebox

7

• Rotate the baffle to remove from the firebox through the

door opening

8

5.4 The replacement of the system is the reverse of the previous

operations.

5.5 Do not modify the baffle

Advertising
This manual is related to the following products: