-9-

SECTiON 2: CiRCUiT REQUiREMENTS

Extension Cords

We do not recommend the use of extension cords.
instead, arrange the placement of your equipment
and the installed wiring to eliminate the need for
extension cords.

if you find it absolutely necessary to use an exten-
sion cord at 220V with your machine:

use at least a 16 gauge cord that does not
exceed 50 feet in length!

the extension cord must also contain a
ground wire and plug pin.

A qualified electrician Must size cords over
50 feet long to prevent motor damage.

Serious personal injury could occur if you

connect the machine to the power source

before you have completed the set up pro-

cess. DO NOT connect the machine to the

power source until instructed to do so.

220v Single-Phase

Grounding

in the event of an electrical short, grounding
reduces the risk of electric shock. the grounding
wire in the power cord must be properly connected
to the grounding prong on the plug; likewise, the
outlet must be properly installed and grounded.
All electrical connections must be made in accor-
dance with local codes and ordinances.

Amperage Draw

the Model g0665 motor draws the following
amps under maximum load:

Motor draw ..............................................6 Amps

Power Supply Circuit Requirements

We recommend connecting your machine to a
dedicated and grounded circuit that is rated for
the amperage given below. never replace a circuit
breaker on an existing circuit with one of higher
amperage without consulting a qualified electri-
cian to ensure compliance with wiring codes.

if

you are unsure about the wiring codes in your

area or you plan to connect your machine to a

shared circuit, consult a qualified electrician.

Minimum Circuit size .............................15 Amps

Plug/Receptacle Type

recommended plug/receptacle ...... neMA 6-15

Electrocution or fire could

result if this machine is

not grounded correctly or

if your electrical config-

uration does not comply

with all applicable codes.

Ensure compliance by

checking with a qualified

electrician!

figure 2. neMA 6-15 plug and receptacle.